Skip to content

PLF060 Standard Planetary Gearbox

PLF060 is a square-flange standard planetary gearbox in the PLF series.

ANDANTEX PRODUCT

Choose the L1 or L2 configuration, then match the ratio and motor interface to its drawing. Alternative L2 ratios require confirmation. Check the complete motor dimensions as well as its power rating.

PLF060 Product Model
PLF Square-Flange Spur Gearbox Product Series
PLF060-5-S2-P2 Example Model
L1:3/4/5/7/10;L2:12/15/16/20/25/28/30/35/40/50/70/100 Gear Ratio
16–40 Nm( By Ratio) Rated Output Torque
L1 ≤8 arcmin;L2 ≤12 arcmin Backlash
240 N Maximum Radial Force
8000 rpm Maximum Input Speed
L1 96%;L2 94% Efficiency

Key Technical Specifications

AND-PD-PLF060-001 Technical Data SheetPLF Square-Flange Spur GearboxStandard Planetary Gearbox
ItemParametersDescription
Product SeriesPLF Square-Flange Spur GearboxStandard Planetary Gearbox
Specifications / Frame Size60Model Specifications
Example ModelPLF060-5-S2-P260 Frame Size / 5:1 / P2
Gear RatioL1:3/4/5/7/10;L2:12/15/16/20/25/28/30/35/40/50/70/100L2 of 12, 15 Marked as an Alternative in the Drawing; See the Next Row for Torque by Ratio
Rated Output Torque16–40 Nm( By Ratio)L1:3=27、4/5=40、7=34、10=16;L2:12/15/30=27、16/20/25/28/35/40/50=40、70=34、100=16 Nm
Maximum TorqueOf the Rated Output Torque 1.5 TimesMaximum Output Torque Specified in the Drawing, Varies with the Rated Value for Each Ratio
BacklashL1 ≤8 arcmin;L2 ≤12 arcminStandard Backlash; Select Drawing by Stage Count
Maximum Input Speed8000 rpmMaximum Input Speed Specified in the Drawing
Rated Input Speed4000 rpmRated Input Speed Specified in the Drawing
Output Flange / Square Size60 mmSquare output flange dimension from https://www.andantexcn.com/wp-content/themes/andantex-local-test/site/assets/downloads/plf060/v22/2d/PLF060-servo-l1-11-50-70-2D.jpg. Reference configuration; custom structures may differ.
EfficiencyL1 96%;L2 94%Two-Stage Efficiency Differs
Operating TemperatureStandard Interface -10℃~+90℃Some Custom Interface Drawings Specify -20℃~+80℃; Use the Specific Interface Drawing
Maximum Axial Force220 N2D Maximum Axial Force Specified in the Drawing
Maximum Radial Force240 N2D Maximum Radial Force Specified in the Drawing
WeightL1 0.98 kg;L2 1.26 kgAs Shown 14-50-70 Motor Interface, ±3%; Confirm Other Interfaces against Their Engineering Drawings
IP RatingIP65Verified L1/L2 Standard Interface Drawing
Service Life20000 hService Life Specified in the Drawing

Need a specification that is not listed? Contact us with the required configuration.

MOTOR INTERFACE FINDER

Find PLF060 drawings by motor interface

Select the motor interface and reduction stage to find the matching drawing and STEP model.

QUICK MATCH

Match your motor dimensions

Filter by motor type, reduction stage and mounting dimensions. Open the available files, or request the format you need.

Select Interface ResourcesAfter Publishing Engineering Resources, Filter by Actual Motor Dimensions.
Check the motor drawing for shaft diameter and length, keyway, pilot diameter, mounting hole spacing, threads and flange thickness.
ENGINEERING FILES

PLF060 drawings and STEP models

Choose your configuration below. Use the 2D drawing to check dimensions and the STEP model to check fit in your assembly.

0 2D + 3D File
0 Interface / Stage Combinations
0 Complete Resource Set
Loading Resources…Choose a configuration to review the available files.
No matching configuration? Submit your motor drawing
DOWNLOAD CHECK

Check the configuration before downloading

Match the model, reduction stage and motor interface to the drawing. Custom input or output dimensions require a separate set of files.

Request Engineering Review
FAQ

Selection FAQ

What should I check before selecting PLF060?

Check the reduction stage, selected ratio and the corresponding rated torque, then review the motor shaft dimensions, pilot diameter, mounting-hole spacing, acceleration and deceleration time, inertia and offset loads. Alternative L2 options identified in the drawing require configuration confirmation. Compare the PLF model options before choosing a configuration.

Can PLF060 be configured for a different motor brand?

Review the actual motor drawing first. Confirm the shaft diameter and length, pilot diameter, key dimensions and mounting-hole arrangement before determining the input flange and bushing configuration. Motor brand or power alone does not confirm fit. Use the motor-interface checklist to prepare the dimensions.

Can PLF060 L1 and L2 use the same 2D or 3D drawing?

No. L1 and L2 differ in stage count and overall length. Use the mounting drawing and 3D model for the exact stage and motor interface, even when the same motor is used.

Why keep both 2D and 3D files for a PLF060 stepper interface?

Use the 2D drawing to check dimensions, hole locations and tolerances. Use the 3D model for machine assembly, interference checks and design reuse. Confirm that both files describe the same configuration.

Need help selecting a gearbox?

Send the required ratio, motor drawing, load and installation details for PLF060.

Generate RFQ
2D DRAWING PREVIEW

PLF060 Mounting Dimensions

PLF060 2D Mounting Drawing Preview

Download Original 2D Drawings

ANDANTEX Product search

Catalogue guide · Beta
Guided catalogue search by model code — not AI chat. Searches are not stored.