Skip to content

PLF120 Standard Planetary Gearbox

PLF120 is a square-flange standard planetary gearbox in the PLF series.

ANDANTEX PRODUCT

Choose the reduction stage, ratio and motor interface, then check the drawing for the required output. Custom versions have separate specifications. The L2 16:1 option is not confirmed for PLF120; request engineering confirmation before specifying it.

PLF120 Product Model
PLF Square-Flange Spur Gearbox Product Series
PLF120-5-S2-P2 Example Model
L1:3/4/5/7/10;L2:12/15/20/25/28/30/35/40/50/70/100 Gear Ratio
86–210 Nm( By Ratio) Rated Output Torque
Standard Interface L1 ≤8; L2 ≤12 arcmin Backlash
1240 N Maximum Radial Force
6000 rpm Maximum Input Speed
L1 96%;L2 94% Efficiency

Key Technical Specifications

AND-PD-PLF120-001 Technical Data SheetPLF Square-Flange Spur GearboxStandard Planetary Gearbox
ItemParametersDescription
Product SeriesPLF Square-Flange Spur GearboxStandard Planetary Gearbox
Specifications / Frame Size120Model Specifications
Example ModelPLF120-5-S2-P2120 Frame Size / 5:1 / P2
Gear RatioL1:3/4/5/7/10;L2:12/15/20/25/28/30/35/40/50/70/100L2 The Table Also Includes 16 Compared with, But the Model in That Row Is Listed as PLF1120, Verify before Confirmation
Rated Output Torque86–210 Nm( By Ratio)L1: 3=161, 4/5=210, 7=170, 10=86; L2: 12/15/30=161, 20/25/28/35/40/50=210, 70=170, 100=86 Nm; 16 Ratio Requires Verification
Maximum TorqueOf the Rated Output Torque 1.5 TimesVaries with Rated Output Torque at Each Ratio
BacklashStandard Interface L1 ≤8; L2 ≤12 arcminSome Custom Outputs L1 Drawing Annotation ≤10 or ≤16; Use the Corresponding Engineering Drawing
Maximum Input Speed6000 rpmMaximum Input Speed Specified in the Drawing
Rated Input Speed3500 rpmRated Input Speed Specified in the Drawing
Output Flange / Square Size120 mm (cast: 122 mm)Square output flange dimension from https://www.andantexcn.com/wp-content/themes/andantex-local-test/site/assets/downloads/plf120/v11/2d/plf120-interface-l1-19-55p5-125p9-2D.jpg. Reference configuration; custom structures may differ.
EfficiencyL1 96%;L2 94%Two-Stage Efficiency Differs
Operating TemperatureStandard Interface -10℃~+90℃Some Custom Interface Drawings Specify -20℃~+80℃; Use the Specific Interface Drawing
Maximum Axial Force1000 N2D Maximum Axial Force Specified in the Drawing
Maximum Radial Force1240 N2D Maximum Radial Force Specified in the Drawing
WeightL1 7.08 kg;L2 8.7 kgAs Shown 22-95-115 Motor Interface, ±3%; Confirm Other Interfaces against Their Engineering Drawings
IP RatingIP65Verified L1/L2 Standard Interface Drawing
Service Life20000 hService Life Specified in the Drawing

Need a specification that is not listed? Contact us with the required configuration.

MOTOR INTERFACE FINDER

Find PLF120 drawings by motor interface

Select the motor interface and reduction stage to find the matching drawing and STEP model.

QUICK MATCH

Match your motor dimensions

Filter by motor type, reduction stage and mounting dimensions. Open the available files, or request the format you need.

Select Interface ResourcesAfter Publishing Engineering Resources, Filter by Actual Motor Dimensions.
Check the motor drawing for shaft diameter and length, keyway, pilot diameter, mounting hole spacing, threads and flange thickness.
ENGINEERING FILES

PLF120 drawings and STEP models

Choose your configuration below. Use the 2D drawing to check dimensions and the STEP model to check fit in your assembly.

0 2D + 3D File
0 Interface / Stage Combinations
0 Complete Resource Set
Loading Resources…Choose a configuration to review the available files.
No matching configuration? Submit your motor drawing
DOWNLOAD CHECK

Check the configuration before downloading

Match the model, reduction stage and motor interface to the drawing. Custom input or output dimensions require a separate set of files.

Request Engineering Review
FAQ

Selection FAQ

What needs confirmation before selecting PLF120?

Check the exact reduction stage and ratio, standard or custom-output conditions, and motor interface. Resolve the source entries flagged on this page before treating a configuration as confirmed. Also review acceleration and deceleration time, inertia and offset loads. Use the PLF series comparison to review other model options without assuming that their limits are interchangeable.

Can PLF120 be configured for a different motor brand?

Review the actual motor drawing first. Confirm the shaft diameter and length, pilot diameter, key dimensions and mounting-hole arrangement before determining the input flange and bushing configuration. Motor brand or power alone does not confirm fit. Use the motor-interface checklist to prepare the dimensions.

Need help selecting a gearbox?

Send the required ratio, motor drawing, load and installation details for PLF120.

Generate RFQ
2D DRAWING PREVIEW

PLF120 Mounting Dimensions

PLF120 2D Mounting Drawing Preview

Download Original 2D Drawings

ANDANTEX Product search

Catalogue guide · Beta
Guided catalogue search by model code — not AI chat. Searches are not stored.