Hollow-shaft right-angle gearboxes appear identical from the outside, yet two installation realities split them sharply: how deeply a short shaft can insert into a single-sided blind bore, and how cleanly the gearbox slides off a captive long shaft that cannot be pulled out of the machine frame. For short stub shafts, use a single-sided blind bore such as PVFGB or AT-FC1 and measure the true usable engagement depth (L_eff) on the 2D cross-section rather than the outer housing width. For trapped long continuous shafts (see full through-bore selection principles), avoid standard keyed bores that rust-weld onto the shaft over time—select an external shrink-disc / locking-ring hollow bore (AT-FC / AT090-FC) so mechanics can release radial clamp pressure and slide the gearbox cleanly off the shaft end during maintenance.


1. Through-Bore vs. Single Blind-Bore vs. Non-Through Planetary: Know the Difference
Engineers looking to pass a long shaft straight through a side-driven right-angle housing—or slip onto a short machine stub—must distinguish four distinct internal hollow-bore geometries (full through-bore sizing hub):
| Hollow Architecture | ANDANTEX Series | Long Shaft Passes All the Way Through? | Clamping & Typical Maintenance Removal |
|---|---|---|---|
| 1. Double Keyed Through-Bore | PVFG, AT-FH, KRV (keyed hollow) | Yes — unobstructed end-to-end tunnel | DIN 6885 parallel key + set screw / end washer; prone to fretting corrosion if ungreased |
| 2. Single-Sided Blind Bore | PVFGB, AT-FC1 (single shrink-disc side) | No — open on drive side, closed opposite cap | Ideal for short stubs & washdown safety; verify usable blind depth L_eff before ordering |
| 3. External Shrink-Disc Hollow Bore | AT-FC (double), AT-FC1 (single), KRV shrink-disc | Yes (AT-FC) / One-sided (AT-FC1) | Easiest captive-shaft removal: keyless conical clamping relaxes back to sliding fit |
| 4. Flanged Hollow-Output Planetary | PVBF090 | No — planet carrier sits behind the output bore | Compact high-ratio blind socket; verify thin keyway wall (e.g. Ø20 vs Ø18) on signed 2D PDF |
2. Single Blind-Bore Outputs (PVFGB / AT-FC1): How to Read Real Insertion Depth L_eff
Never assume a gearbox housing that measures 90 mm wide lets you insert 90 mm of shaft, or that a 15 mm stub can safely drive full rated torque. Before ordering a single blind-bore unit like PVFGB090 or PVBF090, inspect four exact dimensions directly on the 2D cross-section CAD drawing:
- 1. Bottoming Shoulder & Internal Snap-Ring Groove (
L_bore): Blind bores normally machine a reduced-diameter internal clearance pocket or retaining circlip groove at the back end—reducing smoothH7contact length well below outer casing width. - 2. Minimum Keyway or Shrink-Disc Engagement (
L_eff ≥ 1.2–1.5 × D): For keyed bores, ensure the engaged key length reaches at least1.2–1.5×shaft diameter (for example,24–30 mmactive key engagement on aØ20 mmstub). For shrink-disc bores (AT-FC1), your solid machine shaft must extend all the way underneath the full width of the outer locking sleeve—never clamp a shrink disc over an empty hollow sleeve section! - 3. Check Keyway Wall Thickness on High-Ratio Hollow Planetaries: On compact hollow-output planetaries such as PVBF090, stepping bore size from
Ø18 mm(56 Nmrated) up toØ20 mm(96 Nmat100:1) leaves a thinner steel hub wall under the keyway slot, requiring signed2Ddrawing confirmation before production. - 4. Leave
1–2 mmEnd-Play Clearance: Design your stub shoulder or retention bolt so the shaft tip stops1–2 mmshort of the blind bottom shoulder, preventing axial wedging against internal bevel bearings.
3. Captive Long Shaft That Cannot Be Pulled Out: Why Shrink Discs Beat Keyed Bores on Maintenance
When a 1.5 m drive shaft is captured between welded pillow blocks, sprockets, and machine side frames, servicing a failed gearbox requires unbolting the torque arm and sliding the gearbox straight off one shaft end. Standard keyed hollow bores (AT-FH / PVFG) frequently lock solid within a year: tiny cyclic micro-slips inside the key clearance grind out red iron-oxide fretting powder that swells and welds the H7 bore onto the shaft, forcing torch cutting or hydraulic pullers in cramped frames (see tight side-frame clearances).
Select an External Shrink-Disc / Locking-Ring Gearbox (AT-FC / KRV shrink-disc option) instead, and add three simple shaft-design details so maintenance takes 10 minutes instead of a full machine teardown:
- Release Bolts = Instant Clearance Fit: Backing out the external locking-ring screws relaxes all radial grip, returning the bore to an effortless
H7/g6slide with zero keyway burrs or fretting scars—even under frequent reversing loads (rapid reversing rules). - Undercut the Non-Engaged Shaft Span by
0.5–1.0 mm: Machine only the short gearbox journal seat to precisionh6/g6diameter (D) and turn the remaining trapped run down slightly (D - 0.5 mmtoD - 1.0 mm) so the gearbox only has to slide tight over80–100 mmrather than dragging across corroded shaft length. - Respect the Anti-Seize Rule & Add Puller Jack Holes: Coat keyed hollow bores (
AT-FH/PVFG) with molybdenum-disulfide anti-seize paste at assembly—but keep shrink-disc friction bore contact clean and dry (never grease the clamping zone insideAT-FC!). Always tap M6/M8 jack-screw holes in end retention washers for clean mechanical breakaway.
Frequently Asked Questions (FAQ)
Q1: Where do I find the exact usable blind-bore insertion depth on PVFGB090 or PVBF090?
Open the model's 2D PDF dimension sheet (PVFGB090 / PVBF090) and read both total bore pocket depth from the mounting face and usable keyway length, or ask our Engineering RFQ Desk to highlight the safe stub range in red before you turn your shaft.
Q2: Can a shrink-disc hollow bore (AT-FC) hold full peak torque without slipping on a smooth shaft?
Yes—when your solid shaft uses h6/g6 ground steel (Ra ≤ 1.6 μm), remains dry/degreased in the clamping band, and extends completely through the locking ring's clamp zone, AT-FC transmits rated and shock torque with zero backlash and zero keyway stress risers.
Q3: Can ANDANTEX supply custom bore diameters or motor adapters for odd captive shafts?
Yes—standard stock (~60% availability) covers common metric bores, while custom CNC motor input adapters (MOQ = 1 in 3–5 working days) and split reduction sleeves adapt non-standard motors cleanly after drawing sign-off.