Retrofitting or packaging a machine where the ball screw or trapezoidal lead screw stands vertically while the motor must lie horizontally inside a low-height base frame is a classic right-angle transmission problem. Yes—ANDANTEX can match an existing vertical screw journal directly using compact 90° right-angle spiral bevel, planetary, or hypoid gearboxes, provided you verify three critical mechanical boundaries before bolting up: axial screw thrust isolation, vertical upward (V6) sealing, and lower base height clearance.


1. Check 1 — Axial Screw Thrust: Existing BK Bearing Block vs. Hanging Thrust on the Gearbox
Every vertical screw carries downward (or bidirectional push/pull) axial thrust F_a straight down its shaft line. Determine how your existing machine supports that vertical screw before picking a solid or hollow right-angle gearbox (compare internal gearbox bearings vs. external thrust blocks):
- Case A — Your Vertical Screw Already Sits in Its Own
BKFixed Angular-Contact Bearing Block: Never lock a hollow-bore gearbox rigidly onto the base frame while clamping onto a bearing-supported screw—that creates an over-constrained 3-bearing stack that binds as the screw warms up. Instead, either:- Mount a solid-shaft
90°gearbox (PVFD,AT-FL1,PAMG, orPVFA) horizontally inside the base and join its upward shaft to the vertical screw tail via an elastomeric jaw or bellows coupling (leaving1–2 mmaxial float), OR - Slide a hollow shrink-disc unit (
AT-FC/KRV) onto the screw journal with a compliant rubber-bushed torque arm so the gearbox housing floats freely.
- Mount a solid-shaft
- Case B — The Vertical Screw Has No Bottom Thrust Bearing and Rests on the Gearbox: Verify total vertical payload, acceleration, and process pressing force strictly against the gearbox datasheet's maximum axial force
F_a(for example,AT120-FL1handles up to1,900 Nmax axial force, while light bevel units handle lower thrust). Above~1,500–2,000 Nor under shock pressing loads, always insert an externalBKthrust bearing pillow block ahead of the gearbox!
2. Selecting the Best 90° Architecture for Shallow Base Frames
| Right-Angle Series | Base Height Profile | Ratio Range | Connection to Vertical Screw Tail | Best Retrofitting Scenario |
|---|---|---|---|---|
KRV Servo Hypoid | Ultra-low profile (thin vertical stack) | 7.5:1–100:1 | Hollow bore (keyed or shrink disc) / solid | Shallowest base enclosures needing high ratio in one compact 90° stage |
AT-FC / AT-FC1 Bevel | Compact cube + locking ring | 1:1–10:1+ | Keyless external shrink disc on screw tail | Existing smooth/hardened screw tails without keyways or needing easy vertical pull-off (shrink-disc guide) |
PAMG / PVFA Planetary | Moderate 90° + square flange | 3:1–100:1 | Solid output shaft + zero-backlash coupling | High-precision servo screw lifts requiring ≤ 5–8 arcmin & 3,000–6,000 rpm input |
AT-FL1 / PVFD Bevel | Rigid cast/machined block | 1:1–10:1 (L2 up to 50:1) | Solid keyed upward output shaft + coupling | High-speed 1:1–5:1 ball screws (ratio check) and synchronized multi-screw drives |
3. Check 2 & Check 3: Upward V6 Sealing, Base Height & Four-Step Coupling Audit
Pointing a gearbox output shaft straight upward (commonly called V6 or vertical shaft-up orientation) flips two everyday risks into focus (compare vertical/inverted oil-plug and clamping access rules):
- Check
V6Upper-Bearing Lubrication & Falling Debris Protection: Factory grease-sealed servo units (PVFD,PAMG,PVFA,KRV, and compactATframes) run cleanly in360°orientations without starving the top output bearing; for larger oil-bath housings, confirm upward fill level so the top bearing stays splash-lubricated. Add a simple top aluminum labyrinth shield or slinger collar over the upward oil seal so screw grease, water, or machining chips never pool on the lip seal. - Measure Exposed Screw Stub Diameter, Keyway & Usable Length: Measure your vertical screw's bottom drive journal (e.g.,
Ø12,Ø15,Ø20 mm), check whether aDIN 6885keyway exists, and compare against usable blind-bore depth if sliding a hollow box upward onto the screw (check blind-boreL_effrules). - Measure Base Floor-to-Screw-End Stack Height: Compare total vertical clearance inside the machine base against gearbox centerline height + motor body width/junction box overhang + coupling height (hollow-bore
KRVorAT-FC1saves coupling height when vertical base headroom is under150–180 mm). - Match Existing Motor & Screw With
MOQ = 1CNC Interfaces: With roughly60%standard models stocked and custom CNC input flanges or adapters built atMOQ = 1in3–5working days, ANDANTEX delivers a verified2D PDF / 3D STEPoverlay showing exact base clearance, horizontal motor clamping wrench orientation, and screw coupling hardware before production.
Frequently Asked Questions (FAQ)
Q1: What if my existing vertical screw tail has a threaded end or non-standard imperial diameter?
Do not force a loose metric bushing onto an imperial or stepped screw tail. Coupling via a precision custom-bored jaw/bellows coupling or ordering an MOQ = 1 custom stepped sleeve preserves concentricity and prevents screw whipping.
Q2: Can I mount the horizontal motor sideways inside the base if the safety cover leaves zero wrench room for clamping?
Yes—simply clock the 4-bolt motor adapter 90°/180° upward before dropping the unit into the base, pre-torque on the bench, or request a custom-clocked clamping access hole (tight-guard wrench access solutions).
Q3: Does a vertical ball screw driven by a 90° planetary/bevel box need a power-off holding brake?
Almost always yes—because high-efficiency ball screws back-drive under load as soon as motor current drops. Specify a 24 V DC brake servo motor or load-side brake (vertical brake & anti-drop guide) and send your base sketch to our Engineering RFQ Desk.